Circuit Breaker>>Motor Protection Circuit Breaker>>DZ518 Series


Product Features

 

DZ518(GV2 GV3)series motor protecting breaker adopts the design of module,It has beautifulshape,small value,complete range of function and reliable performance.DZ518 series is conformity with IEC60947.2, IEC60947-4.1, andEN60947-1 standards,Switch an contactor can make up the starting of the motor The prection grade of the case of DZ518 series can reach IP55. DZ518 series has three types of products. DZ518(GV2-M)series is button-controlling motor with hot magnetic protecting breaker,DZ518(GV20-Rs)series is switch-shifting controlling motor with hot mangnetic protecing breaker,DZ518(GV2-LS) serrues is switch-shifting controlling motor with magnetc protecting breaker.

 

Specification

 

DZ518(GV2-M)(ME)
DZ518(GV2-RS)
DZ518(GV2-LS)(LE)
M01C
0.1-0.16
RS01C
0.1-0.16
M02C
0.16-0.25
RS02C
0.16-0.25
M03C
0.25-0.40
RS03C
0.25-0.40
LS03
0.25-0.40
M04C
0.40-0.63
RS04C
0.40-0.63
LS04
0.40-0.63
MO5C
0.63-1
RS05C
0.63-1
LS05
0.63-1
MO6C
1-1.6
RS06C
1-1.6
LS06
1-1.6
MO7C
1.6-2.5
RS07C
1.6-2.5
LS07
1.6-2.5
MO8C
2.5-4
RS08C
2.5-4
LS08
2.5-4
M10C
4-6.3
RS10C
4-6.3
LS10
4-6.3
M14C
6-10
RS14C
6-10
LS14
6-10
M16C
9-14
RS16C
9-14
LS16
9-14
M18C
10-16
RS18C
10-16
LS18
10-16
M20C
13-18
RS20C
13-18
LS20
13-18
M21C
17-23
RS21C
17-23
LS21
17-23
M22C
20-25
RS22C
20-25
LS22
20-25
M32C
24-32
RS32C
24-32
LS22
20-25

 

The rated power of three-phase electromtor controlled by breaker(GV2 motor circuit breaker)

 

Adjusting range of rated current (A)
Standard power of three-phase electromotor( KW) AC-3
50/60Hz
230/240V
400V
415V
440V
500V
690V
0.1-0.16
-
-
-
-
-
-
0.16-0.25
-
-
-
-
-
-
0.25-0.4
-
-
-
-
-
-
0.4-0.63
-
-
-
-
-
0.37
0.63-1
-
-
-
0.37
0.37
0.55
1-1.6
-
0.37
-
0.55
0.75
1.1
1.6-2.5
-
0.75
0.75
1.1
1.1
1.5
2.5-4
0.37
1.5
1.5
1.5
2.2
3
4-6.3
0.75
2.2
2.2
3
3.7
4
6-10
1.1
4
4
4
5.5
7.5
9-14
2.2
5.5
5.5
7.5
7.8
9
13-18
3
7.5
9
9
9
11
17-23
4
11
11
11
11
15
20-25
5.5
11
11
11
11
18.5
24-32
5.5
15
15
15
18.5
23

 

AIR SWITCH OF THE MOTOR

The disjointing current commuting value of breaker in instantmagnetic field

 

Rated current In(A)
Adjusting range(A)
Disjointing current(A)
>0.16
0.1-0.16
1.5
0.25
0.16-0.25
2.4
0.4
0.25-0.4
5
0.63
0.4-0.63
8
1
0.63-1
13
1.6
1-1.6
22.5
2.5
1.6-2.5
33.5
4
2.5-4
51
6.3
4-6.3
8
10
6-10
138
14
9-14
<170
18
13-18
223
23
17-23
327
25
20-25
327
32
24-32
416

 

contacts of accessories

 

Names of accessories Code The types of comtacts Installation place
Instantaneous
auxiliary contacts
AE1 constant-open or constant 1 closed The foront of breaker (1PCS)
AE11 constant-open or constant 1 closed
AE20 two constant open
AN11 constant-open or constant 1 closed the left of breaker (4PCS)
AN20 2constant open
instantaneous
auxiliary contacts
+
Instantaneous
auxiliary contacts
AD1010 constant-open trouble contant-open
AD1001 contant-closed
AD0110 constant-closed trouble contant-open
AD0101 contant-closed
Short circuit contacts AM11  constant-open or constant 1 closed

 

Electric disjointing

 

Names of accessories
Voltage
Code
Installation place
Memo
Lack-voltage disjointing
110-127V 50Hz
AU115
The right of breaker
(1PCS)
110-127V 50Hz
AU225
110-127V 50Hz
AU385
Division disjointing
110-127V 50Hz
AS115
110-127V 50Hz
AS225
110-127V 50Hz
AS385
Be used to the release
of low voltage
110-127V 50Hz
AX115
110-127V 50Hz
AX225
110-127V 50Hz
AX385

 

The protective case of breaker

 

Names of accessories The protection degree of shell Code Memo
External installation shell 1P 41 MC01
-
1P 55 MC02
1P 55 MC03